| 1. Ensure Cube contents are deleted |
| 2. In R/3 go to T- code LBWG and delete contents of set-up table. Choose the correct application area 03 |
| 3. Ensure all other users except self and ALEREMOTE or BW RFC users are locked out. ( you need an outage time in R/3 when you are loading data from R/3) |
| 4. Run T-Code MCNB to set - up stocks. DataSource 2LIS_03_BX, all materials including non-valuated stock |
| 5. Load the set - up table with history data if needed. |
| - T-Code OLI1BW for Material Movements |
| - T-Code OLIZBW for Revaluations |
| 6. From BW load initialisation for 2LIS_03_BX to set the initial stock. Compress this load with a marker update |
| 7. Run an initialisation without data transfer from BW for DataSource 2LIS_03_BF and 2LIS_03_UM |
| 8. Load the historical data as full updates for 2LIS_03_BF and 2LIS_03_UM into the cube. Compress these two loads without a marker update. |
| 9. Make sure that, Job control has already been set - up in R/3. |
| Deltas can now be loaded and compressed with a marker update |